Acoustic Characterization of a 32 × 32 Element PZT-on-ASIC Matrix Transducer for 3D Transesophageal Echocardiography

M. Shabanimotlagh, S. Raghunathan, D. Bera, Zhao Chen, Chao Chen, V. Daeichin, M. Pertijs, J.G. Bosch, N. de Jong, M. Verweij

Research output: Contribution to conferenceAbstractScientific

46 Downloads (Pure)

Abstract

Echocardiography is a portable, safe, and low-cost imaging technique for accurate assessment of the heart. In transesophageal echocardiography (TEE) the esophagus is utilized as the imaging window to examine the cardiac anatomy and function. In conventional TEE probes, a one-dimensional (1D) ultrasound array is employed to obtain two-dimensional (2D) cross-sectional images of the heart. Since cardiac morphology, leakage of valves and function of the outflow tracts are all three-dimensional (3D) phenomena, it is beneficial to interpret them from 3D images. Therefore, there is high clinical demand for matrix TEE probes that are capable of providing real-time volumetric images [1]. Several matrix arrays (Philips X7-2t, Siemens V5M TEE, General Electric 6VTD) have been developed for this purpose, however all of them are large in size (~10 cm3) and uncomfortable to use on non-anesthetized patients [2]. We aim to develop a matrix TEE probe with a small head volume (<1 cm3), which is suitable for long term monitoring of cardiac system on adults and in babies. We have developed a prototype of a small matrix TEE probe, which consists of a piezoelectric matrix transducer directly mounted on an Application Specific Integrated Circuit (ASIC). The ASIC performs the task of micro-beamforming, signal amplification and efficient data reduction. The piezoelectric matrix array consist of a 32×32 PZT elements with a pitch of 150 μm × 150 μm. The transmit aperture consists of 8×8 elements at the centre of the array, which are directly wired out to the ultrasound system. The remaining 864 elements are used in receive and are organized in 96 sub-arrays of 3×3 elements to reduce the cable count with a factor of 9. The signals from the individual elements in a sub-array are combined to a single output signal using a micro-beamformer on the ASIC. The micro-beamformer allows pre-steering of 0◦, ±17◦, and ±37◦ angles in both lateral and elevation directions. By recording datasets for different pre-steering angles, and by processing and combining them, a large volume image can be constructed. Acoustic performance of the prototype is evaluated in a water tank. The transmit transfer function of a single element is measured by applying a 20 cycle sinusoidal voltage, sweeping from 3 to 8 MHz with steps of 50 kHz. The output pressure is recorded by a calibrated hydrophone. It is found that the transducer has a central frequency of 5 MHz, a bandwidth of 40% and a transmit efficiency of 6.4 kPa/V (at 51 mm). To characterize the micro-beamforming function, three delay angles of 0◦, 17◦ and 37◦ were programmed. While transmitting with a well-defined external source, the output voltage from a sub-group was recorded from -50◦ to +50◦ degrees. We observe that the theoretical values of the beam profile agree well with the measurement results, especially with regard to the position of the grating lobes and side lobes.
Original languageEnglish
Pages1-1
Publication statusPublished - 2017
Event6th Dutch Bio-Medical Engineering Conference, BME 2017 - Egmond aan Zee, Netherlands
Duration: 26 Jan 201727 Jan 2017
Conference number: 6

Conference

Conference6th Dutch Bio-Medical Engineering Conference, BME 2017
Abbreviated titleBME 2017
Country/TerritoryNetherlands
CityEgmond aan Zee
Period26/01/1727/01/17

Bibliographical note

Op lijst van EWI - EI

Fingerprint

Dive into the research topics of 'Acoustic Characterization of a 32 × 32 Element PZT-on-ASIC Matrix Transducer for 3D Transesophageal Echocardiography'. Together they form a unique fingerprint.

Cite this