Light Emitting Diode (LED) luminaires and lamps are energy-saving and environmental friendly alternatives to traditional lighting products. However, current luminous flux depreciation test at luminaire and lamp level requires a minimum of 6000 h testing, which is even longer than the product development cycle time. This paper develops an accelerated test method for luminous flux depreciation to reduce the test time within 2000 h at an elevated temperature. The method is based on lumen maintenance boundary curve, obtained from a collection of LED source lumen depreciation data, known as LM-80 data. The exponential decay model and Arrhenius acceleration relationship are used to determine the new threshold of lumen maintenance and acceleration factor. The proposed method has been verified by a number of simulation studies and experimental data for a wide range of LED luminaire and lamp types from both internal and external experiments. The qualification results obtained by the accelerated test method agree well with traditional 6000 h tests.
Original languageEnglish
Pages (from-to)84-92
Number of pages9
JournalReliability Engineering & System Safety
Volume147
Issue numberMarch
DOIs
Publication statusPublished - 2016

    Research areas

  • LED luminaire and lamp, Luminous flux depreciation, Lumen maintenance, Accelerated test, LM-80, Boundary curve