TY - JOUR
T1 - Evaluation of an Open Source Registration Package for Automatic Contour Propagation in Online Adaptive Intensity-Modulated Proton Therapy of Prostate Cancer
AU - Qiao, Yuchuan
AU - Jagt, Thyrza
AU - Hoogeman, Mischa
AU - Lelieveldt, Boudewijn
AU - Staring, Marius
PY - 2019
Y1 - 2019
N2 - Objective: Our goal was to investigate the performance of an open source deformable image registration package, elastix, for fast and robust contour propagation in the context of online-adaptive intensity-modulated proton therapy (IMPT) for prostate cancer. Methods: A planning and 7–10 repeat CT scans were available of 18 prostate cancer patients. Automatic contour propagation of repeat CT scans was performed using elastix and compared with manual delineations in terms of geometric accuracy and runtime. Dosimetric accuracy was quantified by generating IMPT plans using the propagated contours expanded with a 2 mm (prostate) and 3.5 mm margin (seminal vesicles and lymph nodes) and calculating dosimetric coverage based on the manual delineation. A coverage of V95% ≥ 98% (at least 98% of the target volumes receive at least 95% of the prescribed dose) was considered clinically acceptable. Results: Contour propagation runtime varied between 3 and 30 s for different registration settings. For the fastest setting, 83 in 93 (89.2%), 73 in 93 (78.5%), and 91 in 93 (97.9%) registrations yielded clinically acceptable dosimetric coverage of the prostate, seminal vesicles, and lymph nodes, respectively. For the prostate, seminal vesicles, and lymph nodes the Dice Similarity Coefficient (DSC) was 0.87 ± 0.05, 0.63 ± 0.18, and 0.89 ± 0.03 and the mean surface distance (MSD) was 1.4 ± 0.5 mm, 2.0 ± 1.2 mm, and 1.5 ± 0.4 mm, respectively. Conclusion: With a dosimetric success rate of 78.5–97.9%, this software may facilitate online adaptive IMPT of prostate cancer using a fast, free and open implementation.
AB - Objective: Our goal was to investigate the performance of an open source deformable image registration package, elastix, for fast and robust contour propagation in the context of online-adaptive intensity-modulated proton therapy (IMPT) for prostate cancer. Methods: A planning and 7–10 repeat CT scans were available of 18 prostate cancer patients. Automatic contour propagation of repeat CT scans was performed using elastix and compared with manual delineations in terms of geometric accuracy and runtime. Dosimetric accuracy was quantified by generating IMPT plans using the propagated contours expanded with a 2 mm (prostate) and 3.5 mm margin (seminal vesicles and lymph nodes) and calculating dosimetric coverage based on the manual delineation. A coverage of V95% ≥ 98% (at least 98% of the target volumes receive at least 95% of the prescribed dose) was considered clinically acceptable. Results: Contour propagation runtime varied between 3 and 30 s for different registration settings. For the fastest setting, 83 in 93 (89.2%), 73 in 93 (78.5%), and 91 in 93 (97.9%) registrations yielded clinically acceptable dosimetric coverage of the prostate, seminal vesicles, and lymph nodes, respectively. For the prostate, seminal vesicles, and lymph nodes the Dice Similarity Coefficient (DSC) was 0.87 ± 0.05, 0.63 ± 0.18, and 0.89 ± 0.03 and the mean surface distance (MSD) was 1.4 ± 0.5 mm, 2.0 ± 1.2 mm, and 1.5 ± 0.4 mm, respectively. Conclusion: With a dosimetric success rate of 78.5–97.9%, this software may facilitate online adaptive IMPT of prostate cancer using a fast, free and open implementation.
KW - elastix
KW - image registration
KW - intensity modulated proton therapy
KW - open source software
KW - prostate cancer
UR - http://www.scopus.com/inward/record.url?scp=85076689276&partnerID=8YFLogxK
U2 - 10.3389/fonc.2019.01297
DO - 10.3389/fonc.2019.01297
M3 - Article
AN - SCOPUS:85076689276
SN - 2234-943X
VL - 9
SP - 1
EP - 13
JO - Frontiers in Oncology
JF - Frontiers in Oncology
M1 - 1297
ER -