Standard

In-operation field-of-view retrieval (IFR) for satellite and ground-based DOAS-type instruments applying coincident high-resolution imager data. / Sihler, Holger; Lübcke, Peter; Lang, Rüdiger; Beirle, Steffen; de Graaf, Martin; Hörmann, Christoph; Lampel, Johannes; Penning de Vries, Marloes; Remmers, Julia; Trollope, Ed; Wang, Yang; Wagner, Thomas.

In: Atmospheric Measurement Techniques, Vol. 10, No. 3, 09.03.2017, p. 881-903.

Research output: Contribution to journalArticleScientificpeer-review

Harvard

Sihler, H, Lübcke, P, Lang, R, Beirle, S, de Graaf, M, Hörmann, C, Lampel, J, Penning de Vries, M, Remmers, J, Trollope, E, Wang, Y & Wagner, T 2017, 'In-operation field-of-view retrieval (IFR) for satellite and ground-based DOAS-type instruments applying coincident high-resolution imager data', Atmospheric Measurement Techniques, vol. 10, no. 3, pp. 881-903. https://doi.org/10.5194/amt-10-881-2017

APA

Sihler, H., Lübcke, P., Lang, R., Beirle, S., de Graaf, M., Hörmann, C., Lampel, J., Penning de Vries, M., Remmers, J., Trollope, E., Wang, Y., & Wagner, T. (2017). In-operation field-of-view retrieval (IFR) for satellite and ground-based DOAS-type instruments applying coincident high-resolution imager data. Atmospheric Measurement Techniques, 10(3), 881-903. https://doi.org/10.5194/amt-10-881-2017

Vancouver

Sihler H, Lübcke P, Lang R, Beirle S, de Graaf M, Hörmann C et al. In-operation field-of-view retrieval (IFR) for satellite and ground-based DOAS-type instruments applying coincident high-resolution imager data. Atmospheric Measurement Techniques. 2017 Mar 9;10(3):881-903. https://doi.org/10.5194/amt-10-881-2017

Author

Sihler, Holger ; Lübcke, Peter ; Lang, Rüdiger ; Beirle, Steffen ; de Graaf, Martin ; Hörmann, Christoph ; Lampel, Johannes ; Penning de Vries, Marloes ; Remmers, Julia ; Trollope, Ed ; Wang, Yang ; Wagner, Thomas. / In-operation field-of-view retrieval (IFR) for satellite and ground-based DOAS-type instruments applying coincident high-resolution imager data. In: Atmospheric Measurement Techniques. 2017 ; Vol. 10, No. 3. pp. 881-903.

BibTeX

@article{f531a003492d444eb8eeeae7f9fccd6a,
title = "In-operation field-of-view retrieval (IFR) for satellite and ground-based DOAS-type instruments applying coincident high-resolution imager data",
abstract = "Knowledge of the field of view (FOV) of a remote sensing instrument is particularly important when interpreting their data and merging them with other spatially referenced data. Especially for instruments in space, information on the actual FOV, which may change during operation, may be difficult to obtain. Also, the FOV of ground-based devices may change during transportation to the field site, where appropriate equipment for the FOV determination may be unavailable.This paper presents an independent, simple and robust method to retrieve the FOV of an instrument during operation, i.e. the two-dimensional sensitivity distribution, sampled on a discrete grid. The method relies on correlated measurements featuring a significantly higher spatial resolution, e.g. by an imaging instrument accompanying a spectrometer. The method was applied to two satellite instruments, GOME-2 and OMI, and a ground-based differential optical absorption spectroscopy (DOAS) instrument integrated in an SO2 camera. For GOME-2, quadrangular FOVs could be retrieved, which almost perfectly match the provided FOV edges after applying a correction for spatial aliasing inherent to GOME-type instruments. More complex sensitivity distributions were found at certain scanner angles, which are probably caused by degradation of the moving parts within the instrument. For OMI, which does not feature any moving parts, retrieved sensitivity distributions were much smoother compared to GOME-2. A 2-D super-Gaussian with six parameters was found to be an appropriate model to describe the retrieved OMI FOV. The comparison with operationally provided FOV dimensions revealed small differences, which could be mostly explained by the limitations of our IFR implementation. For the ground-based DOAS instrument, the FOV retrieved using SO2-camera data was slightly smaller than the flat-disc distribution, which is assumed by the state-of-the-art correlation technique. Differences between both methods may be attributed to spatial inhomogeneities.In general, our results confirm the already deduced FOV distributions of OMI, GOME-2, and the ground-based DOAS. It is certainly applicable for degradation monitoring and verification exercises. For satellite instruments, the gained information is expected to increase the accuracy of combined products, where measurements of different instruments are integrated, e.g. mapping of high-resolution cloud information, incorporation of surface climatologies. For the SO2-camera community, the method presents a new and efficient tool to monitor the DOAS FOV in the field.",
keywords = "Satellite imagery",
author = "Holger Sihler and Peter L{\"u}bcke and R{\"u}diger Lang and Steffen Beirle and {de Graaf}, Martin and Christoph H{\"o}rmann and Johannes Lampel and {Penning de Vries}, Marloes and Julia Remmers and Ed Trollope and Yang Wang and Thomas Wagner",
year = "2017",
month = mar,
day = "9",
doi = "10.5194/amt-10-881-2017",
language = "English",
volume = "10",
pages = "881--903",
journal = "Atmospheric Measurement Techniques",
issn = "1867-1381",
publisher = "Copernicus",
number = "3",

}

RIS

TY - JOUR

T1 - In-operation field-of-view retrieval (IFR) for satellite and ground-based DOAS-type instruments applying coincident high-resolution imager data

AU - Sihler, Holger

AU - Lübcke, Peter

AU - Lang, Rüdiger

AU - Beirle, Steffen

AU - de Graaf, Martin

AU - Hörmann, Christoph

AU - Lampel, Johannes

AU - Penning de Vries, Marloes

AU - Remmers, Julia

AU - Trollope, Ed

AU - Wang, Yang

AU - Wagner, Thomas

PY - 2017/3/9

Y1 - 2017/3/9

N2 - Knowledge of the field of view (FOV) of a remote sensing instrument is particularly important when interpreting their data and merging them with other spatially referenced data. Especially for instruments in space, information on the actual FOV, which may change during operation, may be difficult to obtain. Also, the FOV of ground-based devices may change during transportation to the field site, where appropriate equipment for the FOV determination may be unavailable.This paper presents an independent, simple and robust method to retrieve the FOV of an instrument during operation, i.e. the two-dimensional sensitivity distribution, sampled on a discrete grid. The method relies on correlated measurements featuring a significantly higher spatial resolution, e.g. by an imaging instrument accompanying a spectrometer. The method was applied to two satellite instruments, GOME-2 and OMI, and a ground-based differential optical absorption spectroscopy (DOAS) instrument integrated in an SO2 camera. For GOME-2, quadrangular FOVs could be retrieved, which almost perfectly match the provided FOV edges after applying a correction for spatial aliasing inherent to GOME-type instruments. More complex sensitivity distributions were found at certain scanner angles, which are probably caused by degradation of the moving parts within the instrument. For OMI, which does not feature any moving parts, retrieved sensitivity distributions were much smoother compared to GOME-2. A 2-D super-Gaussian with six parameters was found to be an appropriate model to describe the retrieved OMI FOV. The comparison with operationally provided FOV dimensions revealed small differences, which could be mostly explained by the limitations of our IFR implementation. For the ground-based DOAS instrument, the FOV retrieved using SO2-camera data was slightly smaller than the flat-disc distribution, which is assumed by the state-of-the-art correlation technique. Differences between both methods may be attributed to spatial inhomogeneities.In general, our results confirm the already deduced FOV distributions of OMI, GOME-2, and the ground-based DOAS. It is certainly applicable for degradation monitoring and verification exercises. For satellite instruments, the gained information is expected to increase the accuracy of combined products, where measurements of different instruments are integrated, e.g. mapping of high-resolution cloud information, incorporation of surface climatologies. For the SO2-camera community, the method presents a new and efficient tool to monitor the DOAS FOV in the field.

AB - Knowledge of the field of view (FOV) of a remote sensing instrument is particularly important when interpreting their data and merging them with other spatially referenced data. Especially for instruments in space, information on the actual FOV, which may change during operation, may be difficult to obtain. Also, the FOV of ground-based devices may change during transportation to the field site, where appropriate equipment for the FOV determination may be unavailable.This paper presents an independent, simple and robust method to retrieve the FOV of an instrument during operation, i.e. the two-dimensional sensitivity distribution, sampled on a discrete grid. The method relies on correlated measurements featuring a significantly higher spatial resolution, e.g. by an imaging instrument accompanying a spectrometer. The method was applied to two satellite instruments, GOME-2 and OMI, and a ground-based differential optical absorption spectroscopy (DOAS) instrument integrated in an SO2 camera. For GOME-2, quadrangular FOVs could be retrieved, which almost perfectly match the provided FOV edges after applying a correction for spatial aliasing inherent to GOME-type instruments. More complex sensitivity distributions were found at certain scanner angles, which are probably caused by degradation of the moving parts within the instrument. For OMI, which does not feature any moving parts, retrieved sensitivity distributions were much smoother compared to GOME-2. A 2-D super-Gaussian with six parameters was found to be an appropriate model to describe the retrieved OMI FOV. The comparison with operationally provided FOV dimensions revealed small differences, which could be mostly explained by the limitations of our IFR implementation. For the ground-based DOAS instrument, the FOV retrieved using SO2-camera data was slightly smaller than the flat-disc distribution, which is assumed by the state-of-the-art correlation technique. Differences between both methods may be attributed to spatial inhomogeneities.In general, our results confirm the already deduced FOV distributions of OMI, GOME-2, and the ground-based DOAS. It is certainly applicable for degradation monitoring and verification exercises. For satellite instruments, the gained information is expected to increase the accuracy of combined products, where measurements of different instruments are integrated, e.g. mapping of high-resolution cloud information, incorporation of surface climatologies. For the SO2-camera community, the method presents a new and efficient tool to monitor the DOAS FOV in the field.

KW - Satellite imagery

UR - http://resolver.tudelft.nl/uuid:f531a003-492d-444e-b8ee-eae7f9fccd6a

U2 - 10.5194/amt-10-881-2017

DO - 10.5194/amt-10-881-2017

M3 - Article

VL - 10

SP - 881

EP - 903

JO - Atmospheric Measurement Techniques

JF - Atmospheric Measurement Techniques

SN - 1867-1381

IS - 3

ER -

ID: 30639734