Post-tensioned structural glass beams, experimental investigations

Christian Louter, Arno Pérez, Thibaut Jordan, Jean-Paul Lebet

Research output: Chapter in Book/Conference proceedings/Edited volumeConference contributionScientificpeer-review

7 Citations (Scopus)

Abstract

In this study the structural response of post-tensioned structural glass beams is investigated. This is done through four-point bending tests on two series of post-tensioned glass beam specimens. The beams consist of three layers of annealed float glass and are posttensioned by means of two stainless steel tendons positioned along the upper and lower edge of the beams. In addition, a series of reference beams, with identical geometry but without tendons, is tested. From the results it is concluded that post-tensioning a glass beam is a feasible concept, which provides the beams enhanced initial breakage strength and enhanced post-breakage performance. More specifically, the post-tensioned beams reach up to 80% higher initial breakage loads than the reference beams. Furthermore the post-tensioned glass beams reach postbreakage load levels up to 200% of their initial glass breakage load and demonstrate highly ductile post-breakage response. Further studies will focus in more detail on this promising concept of post-tensioning glass beams.
Original languageUndefined/Unknown
Title of host publicationCOST Action TU0905, Mid-term Conference on Structural Glass
EditorsJan Belis, Christian Louter, Danijel Mocibob
Place of PublicationLondon
PublisherTaylor and Francis
Pages277-284
Number of pages8
ISBN (Print)978-1-138-00044-5
Publication statusPublished - 2013
EventCOST action TU0905 mid-term conference on structural glass - Porec, Croatia
Duration: 18 Apr 201319 Apr 2013

Conference

ConferenceCOST action TU0905 mid-term conference on structural glass
Abbreviated titleCOST action TU0905
Country/TerritoryCroatia
CityPorec
Period18/04/1319/04/13