Abstract

We present well-resolved RANS simulations of a high-aspect-ratio generic cooling duct configuration consisting of an adiabatic straight feed line followed by a heated straight section ending with a 90° bend. The configuration is asymmetrically heated with a temperature difference of ∆T = 40 K. As fluid liquid water is used at a Reynolds number of Reb = 110 × 10 3. The setup follows an experimental reference case, which has also been investigated using a well-resolved LES. The current investigation focuses on the prediction capabilities of different RANS turbulence closure models for the duct flow field, defined by the interaction of secondary flows and turbulent heat transfer. In the straight duct only turbulence-induced secondary flow is present, which becomes weaker along the heated duct due to the viscosity reduction, leading in turn to a reduced mixing. In the curved section, the stronger pressure-induced secondary flow superimposes the turbulence-induced one increasing the mixing of hot and cold fluid. A well-resolved LES serves as comparison database for the straight duct results.

Original languageEnglish
Title of host publicationAIAA Scitech 2020 Forum
Subtitle of host publication6-10 January 2020, Orlando, FL
PublisherAmerican Institute of Aeronautics and Astronautics Inc. (AIAA)
Number of pages19
ISBN (Electronic)978-1-62410-595-1
DOIs
Publication statusPublished - 2020
EventAIAA Scitech 2020 Forum - Orlando, United States
Duration: 6 Jan 202010 Jan 2020

Publication series

NameAIAA Scitech 2020 Forum
Volume1 PartF

Conference

ConferenceAIAA Scitech 2020 Forum
Country/TerritoryUnited States
CityOrlando
Period6/01/2010/01/20

Fingerprint

Dive into the research topics of 'Prediction Capability of RANS Turbulence Models for Asymmetrically Heated High-Aspect-Ratio Duct Flows'. Together they form a unique fingerprint.

Cite this