Shape imperfections of reinforced concrete shell roofs

Research output: Contribution to journalArticleScientificpeer-review

1 Citation (Scopus)

Abstract

The precise geometries of three reinforced concrete shell roofs have been measured with a laser scanner. The resulting point cloud has been modelled by NURBS surfaces. Two methods have been developed for determining the shape imperfections with lengths between 0.5 and 5.5 m. The largest observed imperfection amplitude is 80 mm with length of 5 m. The imperfections are represented by a variance spectrum and an extreme value distribution. From this are derived a formula for the characteristic imperfection amplitude and the partial safety factor.
Original languageEnglish
Article number4
Pages (from-to)177-192
JournalHeron
Volume61
Issue number3
Publication statusPublished - 2016

Keywords

  • Shell structures
  • geometrical imperfections
  • laser scanner
  • variance spectrum
  • extreme value distribution
  • characteristic imperfection
  • partial factors

Fingerprint

Dive into the research topics of 'Shape imperfections of reinforced concrete shell roofs'. Together they form a unique fingerprint.