Standard

The effects of superimposed impulse transients on partial discharge in XLPE cable joint. / Wu, Jiayang; Mor, Armando Rodrigo; Smit, Johan J.

In: International Journal of Electrical Power & Energy Systems, Vol. 110, 2019, p. 497-509.

Research output: Contribution to journalArticleScientificpeer-review

Harvard

APA

Vancouver

Author

Wu, Jiayang ; Mor, Armando Rodrigo ; Smit, Johan J. / The effects of superimposed impulse transients on partial discharge in XLPE cable joint. In: International Journal of Electrical Power & Energy Systems. 2019 ; Vol. 110. pp. 497-509.

BibTeX

@article{fe65064a45e743ea90d2c266bcf6dc55,
title = "The effects of superimposed impulse transients on partial discharge in XLPE cable joint",
abstract = "In practice, cross-linked polyethylene (XLPE) power cables can be subjected to alternating voltage with superimposed impulse transients. Such impulse transients may initiate partial discharges (PD) in insulation defects even below AC inception voltage. An initiated PD may persist under AC, which will cause insulation degradation. This paper investigates the PD behavior in MV XLPE cable accessories under impulse transients. Different scenarios of PD behavior are measured, described and analyzed. Based on the results, the effects of impulse transients on PD are summarized.",
keywords = "XLPE cable, Cable accessories, Insulation defects, Partial discharge (PD), Impulse transients",
author = "Jiayang Wu and Mor, {Armando Rodrigo} and Smit, {Johan J.}",
year = "2019",
doi = "10.1016/j.ijepes.2019.03.031",
language = "English",
volume = "110",
pages = "497--509",
journal = "International Journal of Electrical Power & Energy Systems",
issn = "0142-0615",
publisher = "Elsevier",

}

RIS

TY - JOUR

T1 - The effects of superimposed impulse transients on partial discharge in XLPE cable joint

AU - Wu, Jiayang

AU - Mor, Armando Rodrigo

AU - Smit, Johan J.

PY - 2019

Y1 - 2019

N2 - In practice, cross-linked polyethylene (XLPE) power cables can be subjected to alternating voltage with superimposed impulse transients. Such impulse transients may initiate partial discharges (PD) in insulation defects even below AC inception voltage. An initiated PD may persist under AC, which will cause insulation degradation. This paper investigates the PD behavior in MV XLPE cable accessories under impulse transients. Different scenarios of PD behavior are measured, described and analyzed. Based on the results, the effects of impulse transients on PD are summarized.

AB - In practice, cross-linked polyethylene (XLPE) power cables can be subjected to alternating voltage with superimposed impulse transients. Such impulse transients may initiate partial discharges (PD) in insulation defects even below AC inception voltage. An initiated PD may persist under AC, which will cause insulation degradation. This paper investigates the PD behavior in MV XLPE cable accessories under impulse transients. Different scenarios of PD behavior are measured, described and analyzed. Based on the results, the effects of impulse transients on PD are summarized.

KW - XLPE cable

KW - Cable accessories

KW - Insulation defects

KW - Partial discharge (PD)

KW - Impulse transients

UR - http://www.scopus.com/inward/record.url?scp=85063364865&partnerID=8YFLogxK

U2 - 10.1016/j.ijepes.2019.03.031

DO - 10.1016/j.ijepes.2019.03.031

M3 - Article

VL - 110

SP - 497

EP - 509

JO - International Journal of Electrical Power & Energy Systems

T2 - International Journal of Electrical Power & Energy Systems

JF - International Journal of Electrical Power & Energy Systems

SN - 0142-0615

ER -